System messages – Dell Studio One 19 (1909, Early 2009) User Manual

Page 33

Advertising
background image

31

Using Support Tools

NOTE: To replace parts see the Service

Manual on the Dell Support website at
support.dell.com.

One beep —

BIOS ROM checksum failure.

Possible motherboard failure
Contact Dell (see “Contacting Dell” on page 44).
Two beeps —

No RAM Detected

Remove the memory modules, reinstall

•

one module and restart the computer. If

the computer starts normally, reinstall an

additional module. Continue until you have

identified a faulty module or reinstalled all

modules without an error.
If available, install memory modules of the

•

same type in your computer.
If the problem persists, contact Dell (see

•

“Contacting Dell” on page 44).

Three beeps —

Possible motherboard failure

Contact Dell (see “Contacting Dell” on page 44).

Four beeps —

RAM Read/Write failure

Ensure that no special memory module/

•

memory connector placement requirements

exist (see the Service Manual on the Dell

Support website at support.dell.com).
Verify that the memory modules you are

•

installing are compatible with your computer.
If the problem persists, contact Dell (see

•

“Contacting Dell” on page 44).

Five beeps —

Real Time Clock Failure

Replace the battery.

System Messages

If your computer has an issue or error, it may

display a system message that will help you

identify the cause and action needed to resolve

the issue.

NOTE: If the message you received is not

listed in the following examples, see the

documentation for either the operating

system or the program that was running

Advertising