Dual sas in-port configurations – Dell PowerVault MD3000 User Manual
Page 13

Hardware Installation
13
Dual SAS In-Port Configurations
Figure 2-6 through Figure 2-12 show supported nonredundant and redundant
cabling configurations to MD3000 RAID controller modules with two SAS In
port connectors. Each diagram shows the maximum number of optional
expansion enclosures attached.
Figure 2-6 shows how one, two, three, and four hosts can each be connected
to a RAID controller module nonredundantly. The RAID controller module is
subsequently expanded to two more storage enclosures. The hosts can share
storage space but without redundant paths, if one path were to fail, the server
on that path would be disconnected from the storage array.
Figure 2-6.
Cabling Up to Four Hosts With Nonredundant Data Paths
single-HBA host server
single-HBA host server
RAID controller module 0
RAID controller module 1
MD3000 RAID Enclosure
MD1000 Expansion Enclosure
MD1000 Expansion Enclosure
single-HBA host server
single-HBA host server