Access gateway mode default port mapping, Processor and memory specifications, Appendix a – Dell POWEREDGE M1000E User Manual

Page 35: San i/o module specifications, Appendix a, “san i/o module specifications, Is a pr, Appendix

Advertising
background image

M5424 SAN I/O Module Hardware Reference Manual

25

53-1001082-01

Appendix

A

SAN I/O Module specifications

This appendix provides product specifications and regulatory compliance as a handy reference.

Access Gateway Mode default port mapping

The M5424 SAN I/O Module can contain 24 total ports. Of these, F_Ports are ports 1-16 and
N_Ports are ports 0 and 17-23.

In Access Gateway mode, the SAN I/O Module F_Ports are mapped to N_Ports. This following lists
the factory-default F_Port to N_Port mapping for Access Gateway mode. Since the SAN I/O Module
is shipped with Dynamic Ports on Demand (DPOD) enabled, any out of the 24 ports can be
enabled. Therefore this mapping applies for 12 active ports or, if POD licensing is enabled, for 24
ports. For more information on changing port mapping and managing ports in Access Gateway
Mode, refer to the Access Gateway Administrator’s Guide.

17-20 as N_Port with failover enabled, failback enabled

0, 21-23 as N_Port with failover enabled, failback enabled

1, 2 mapped to 17

3, 4 mapped to 18

5, 6 mapped to 19·

7, 8 mapped to 20

9, 10 mapped to 21·

11, 12 mapped to 22·

13, 14 mapped to 23·

15, 16 mapped to 0

Processor and memory specifications

The processor and memory installed in the SAN I/O Module are shown in

Table 5

.

TABLE 5

Memory Specifications

Memory Type

Value

PowerPC 440EPX processor

667 MHz

SDRAM

512 MB DDR2 - for system memory at 64 bits
wide with 8 ECC operating at 166 MHz

Boot flash

4 MB

Compact flash

512 MB

Advertising