He system. table 1-6 lists, Is not listed in table 1-6, check the – Dell PowerEdge SC 440 User Manual

Page 17

Advertising
background image

About Your System

17

CAUTION:

Many repairs may only be done by a certified service technician. You should only perform

troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.

Table 1-6.

System Messages

Message

Causes

Corrective Actions

A filename cannot contain

any of the following

characters:

\ / : * ? “ < > |

Do not use these characters in filenames.

A required .DLL file was

not found

The application that you are trying to
open is missing an essential file.

Remove and then reinstall the
application.

See the application’s documentation for
installation instructions.

Alert! CPU fan not

detected

The processor cooling fan is faulty or
the fan assembly is not installed
correctly.

Ensure that the processor cooling fan is
properly installed. See "Troubleshooting
System Cooling Problems" on page 86.

Alert! Previous reboot was

due to voltage regulator

failure

See "Getting Help" on page 107.

Alert! System battery

voltage is low

Replace the battery. See
"Troubleshooting the System Battery" on
page 85.

Alert! Unable to initial-

ize all installed memory

One or more memory modules might
be faulty or improperly seated.

See "Troubleshooting System Memory"
on page 87.

If the problem persists, see "Getting
Help" on page 107.

Alert! Card-cage fan

failure.

A card-cage fan is not detected during
POST. The system will halt at the
<F1>/<F2> prompt even if
Keyboard Errors Report option is
disabled in the System Setup
program.

See "Troubleshooting System Cooling
Problems" on page 86.

Alert! Chipset heat sink

not detected.

Ensure heat sink and shroud assembly
are properly attached. See Figure 3-15.

Alert! Cover was

previously removed.

The system was opened.

Information only. To reset the chassis
intrusion switch, see "Using the System
Setup Program" on page 27.