Equipment status, Checking the temperature, fan, and power supply, Checking the status of the fans – Dell POWEREDGE M1000E User Manual

Page 111

Advertising
background image

Fabric OS Troubleshooting and Diagnostics Guide

97

53-1001769-01

Equipment status

10

Equipment status

You can display status for fans, power supply, and temperature.

NOTE

The number of fans, power supplies, and temperature sensors depends on the switch type. For
detailed specifications on these components, refer to the switch hardware reference manual. The
specific output from the status commands varies depending on the switch type.

Checking the temperature, fan, and power supply

1. Log in to the switch as user.

2. Enter the sensorShow command. See the Fabric OS Command Reference for details regarding

the sensor numbers.

3. Check the temperature output.

Look for indications of high or low temperatures.

4. Check the fan speed output.

If any of the fan speeds display abnormal RPMs, replace the fan FRU.

5. Check the power supply status.

If any power supplies show a status other than OK, consider replacing the power supply as
soon as possible.

Checking the status of the fans

1. Connect to the switch and log in as admin.

2. Enter the fanShow command:

switch:admin> fanshow

too shrt

Frames shorter than minimum

too long

Frames longer than maximum

bad eof

Frames with bad end-of-frame delimiters

enc out

Encoding error outside of frames

disc c3

Class 3 frames discarded

link fail

Link failures (LF1 or LF2 states)

loss sync

Loss of synchronization

loss sig

Loss of signal

frjt

Frames rejected with F_RJT

fbsy

Frames busied with F_BSY

TABLE 16

Error summary description (Continued)

Error type

Description