Fabric OS Troubleshooting and Diagnostics Guide

99

53-1001769-01

System message log

10

3 Ok 18 64

Information displays for each temperature sensor in the switch.

The possible temperature status values are:

OK—Temperature is within acceptable range.

FAIL—Temperature is outside of acceptable range. Damage might occur.

Refer to the hardware reference manual for your switch to determine the normal temperature
range.

System message log

The system message log, or RASLog, feature enables messages to be saved across power cycles
and reboots.

The Brocade 48000 director and the Brocade DCX and DCX-4S enterprise-class platforms maintain
the same RASlog for each of the two CP blades. Since all RASlog messages will be routed to the
Active CP, the message CPU ID is added as part of the RASlog message attribute. RASlog message
attribute SLOT is defined to identify the CPU that generated the message.

For example, in the following message the identifier SLOT 6 means the message was generated
from the slot 6 blade main CPU:

2001/01/07-04:03:00, [SEC-1203], 2,SLOT 6 | FFDC | CHASSIS, INFO, C08_1, Login

information: Login successful via TELNET/SSH/RSH. IP Addr: 192.168.38.2050

and the identifier SLOT 6/1 means the message was generated from slot 6 blade Co-CPU.

2001/01/07-04:03:00, [SEC-1203], 2, SLOT 6/1 , | FFDC | CHASSIS, INFO, C08_1,

Login information: Login successful via TELNET/SSH/RSH. IP Addr:

192.168.38.2050

Since RASlog supports Virtual Fabrics and logical switches, the FID (Fabric ID) displays on every
RASlog message to identify the source of the logical switch that generates the message.

The FID can be a number from 0 to 128, and the identifier CHASSIS depends on the instance that
generates the message and that it was generated by a chassis instance. The identifier FID 128
means the message was generated by the default switch instance.

2008/08/01-00:19:44, [LOG-1003], 1, SLOT 6 | CHASSIS, INFO, Silkworm12000, The

log has been cleared.

2008/09/08-06:52:50, [FW-1424], 187, SLOT 6 | FID 128, WARNING, Switch10,

Switch status changed from HEALTHY to DOWN.

For details on error messages, see the Fabric OS Message Reference.

Displaying the system message log, with no page breaks

1. Connect to the switch and log in as admin.

2. Enter the errDump command.

Advertising