Troubleshooting system cooling problems, Troubleshooting a fan – Dell PowerEdge SC1435 User Manual

Page 75

Advertising
background image

Troubleshooting Your System

75

2 Replace the faulty power supply with a new power supply. See "Power Supply" on page 42.

If the problem is not resolved, see ""Getting Help" on page 95."

Problem

Power button is not blinking green and the system does not power up.

Action

1 Ensure that the power cable is properly connected between the power supply and electrical outlet.
2 If you have a UPS, make sure that it is connected properly both to the power supply and to the

electrical outlet.

3 Ensure that the power supply is properly installed by reconnecting the power cables to the system

board. See "Installing the Power Supply" on page 43.

4 Replace the power supply with a new power supply. See "Power Supply" on page 42.
5 If the problem persists, see ""Getting Help" on page 95."

Troubleshooting System Cooling Problems

Problem

Systems management software issues a fan-related error message.

Action

Ensure that none of the following conditions exist:

System cover or cooling shroud is removed.

Ambient temperature is too high.

External airflow is obstructed.

Cables inside the system obstruct airflow.

A cooling fan has failed. See "Troubleshooting a Fan" on page 75.

Troubleshooting a Fan

Problem

System-status indicator is amber.

Systems management software issues a fan-related error message.