Troubleshooting a sas raid controller card – Dell PowerEdge SC1435 User Manual

Page 79

Advertising
background image

Troubleshooting Your System

79

NOTICE:

This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up

all files on the hard drive.

1 Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 85.

Depending on the results of the diagnostics test, proceed as needed through the following steps.

2 If your system has a SAS RAID controller card, perform the following steps.

a

Restart the system and press <Ctrl><C> to enter the RAID configuration utility program.

See the documentation supplied with the RAID controller for information about the
configuration utility.

b

Ensure that the hard drive has been configured correctly for the RAID controller.

c

Exit the configuration utility and allow the system to boot to the operating system.

3 If your system has a SAS controller card, ensure that the required device drivers are installed and are

configured correctly. See the operating system documentation for more information.

4 Check the cable connections inside the system:

a

Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet.

b

Open the system. See "Opening and Closing the System" on page 38.

c

Verify that the cable connections between the hard drive(s) and the drive controller are correct,
whether the connections are to the SATA connectors on the system board (see Figure 6-2) or a
SAS expansion card.

d

Verify that the drive cables are seated in their connectors.

e

Close the system. See "Opening and Closing the System" on page 38.

f

Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, see "Getting Help" on page 95.

Troubleshooting a SAS RAID Controller Card

NOTE:

When troubleshooting a SAS RAID controller card, also see the documentation for your operating system

and the controller card.

Problem

Error message indicates a problem with the SAS RAID controller card.

SAS RAID controller card performs incorrectly or not at all.

Advertising