PowerConnect M6220/M6348/8024/8024F/M8024/M8024-k/
7024/7048/7024P/7048P/7024F/7048R/7048R-RA Release Notes


System Firmware Version 4.1.0.6

Page 21

Known Issues

Summary

User Impact

Workaround

DUT delivers more
power than the PD
requested via LLDP in
high power mode.

DUT may draw more power than negotiated at
short cable lengths. PD may draw more power
than negotiated, but power loss due to cable
impedance is compensated for so that devices
with average or longer cable length will receive
adequate power.

None – system assumes 5.8W average loss
due to cable length and delivers 5.8W extra
power to ensure device receives requested
power.

L3 routing NSF failover
data plane on dynamic
LAG - loss duration up
to 5 seconds for large
configurations

Interruption of voice, video and data service for
duration of loss. Data plane loss during failover
should not exceed 50 ms.

Disable portfast and auto-portfast on physical
ports configured in a LAG.

Trunk mode VLANs
transmit tagged frames
only

Not compatible with other vendors trunk modes.

Administrators can configure “general” mode
VLANs, which transmit PVID frames
untagged and all other VLAN frames tagged.
General mode is compatible with other
vendor’s trunk mode behavior.

Speed/duplex
commands available for
interfaces which require
auto-negotiation

Confusion about how to configure links.

Documentation and CLI prompt clearly states
which commands are applicable to which
interfaces. Only use speed/duplex commands
on fiber interfaces. Only use speed
auto/duplex auto commands on copper
interfaces.

ST : Stack member
response times to ICMP
ping requests in a 12
unit stack are larger
than for stack master

No user impact expected. Observed occasional
outlier response time up to 500 ms for stack
members in a large stack configuration with
heavy traffic. Average response time is well
under 100 ms for stack members. All response
times are well within ping limits.

None required.

Issue with protocol
based VLAN
configuration
migration.

The command vlan protocol group required a
string parameter in earlier versions; now it
requires an integer parameter.

The software recognizes if the group name is
alphanumeric, however it will not work when
the name of the group is numeric (for example
2, 3, etc.).

Read/write user allowed
read only access when
authentication method
is used as TACACS.

The user always gets Read-Only access if using
TACACS as a means for HTTP authentication,
even if the TACACS user is Read/Write capable.

User can configure the same TACACS user
locally and use LOCAL authentication
method for HTTP. The user will be able to get
access based on the local user access level
(Read-write or Read-only).

TFTP gives no reason
for file download
failures.

Generic failure message is issued.

Administrators can ping the TFTP server from
the switch. Administrators should ensure the
TFTP server is available, the requested file is
available, and the permissions are set
correctly.

CLI command stack-
port config rejection
does not display the
cause.

If a user enters an invalid interface, a generic
error message is issued.

Utilize the show stack-port command to
identify stack port configuration issues.

The 'acct-port'
command does not have
'no' version.

The user can configure the acct-port to the
default using the positive form of the command

Configure the acct-port to the default using
the acct-port 1813 command in Radius
accounting mode.

Advertising