Dell POWEREDGE M1000E User Manual

Page 24

Advertising
background image

22

System Firmware Version 4.1.0.6

Summary

User Impact

Workaround

Non-configuration file
getting loaded to
startup-config through
HTTP.

Switch does not utilize invalid configuration file
information. Earlier versions of startup-config
are not available for fallback when overwritten
with an invalid startup-config.

In this case, an invalid configuration file was
downloaded (on purpose) via the web. When
the switch rebooted, it detected that the
configuration file was invalid and overwrote
the start-up config with the default
configuration (an empty configuration). Users
are advised to maintain off-line copies of
switch configurations.

A v6 ping with the v4
header destination
address set to 224.0.0.2
(all routers addr) is not
responded to.

Users are not able to ping over 6to4 tunnels using
IPv6 addresses.

Users can send pure IPv4 pings to the other
end of the tunnel.

Certain packets match
system rules that elevate
the priority for protocol
packets.

Packets may be transmitted out of order when
using priority flow control. Additionally, if the
queue that the packets are put on is not enabled
for lossless PFC, then the packets can be
transmitted even when the port was told to pause.
This may have an effect on connections that
expect packet order to be maintained, e.g. FCoE.

None.