Threshold Settings and Converting Formulas

The following table lists the system sensor’s threshold settings and formulas

for converting the sensor readings.

Table 1-49. Threshold Settings and Converting Formulas

Sensor
Number

Sensor Name The Converting Formula

Upper non-
recoverable

Upper
critical

Upper
non-
critical

Lower non-
recoverable

Lower
critical

Lower
non-
critical

Voltage
05h

12 V Standby Actual_Reading (Volts) = ((Raw_Data x 65) + 60) x 0.001

D4

CA

C1

9C

A6

AF

06h

5 V

Actual_Reading (Volts) = ((Raw_Data x276) + 100) x

0.0001
D0

C7

BE

9A

A3

AC

07h

5 V Standby Actual_Reading (Volts) = ((Raw_Data x 277) + 80) x

0.0001
D0

C7

BE

9A

A3

AC

08h

3.3 V

Actual_Reading (Volts) = ((Raw_Data x 199) + 70) x

0.0001
BF

B7

AE

8D

95

9E

09h

3.3 V Standby Actual_Reading (Volts) = ((Raw_Data x 197) + 100) x

0.0001
C1

B9

B0

8F

97

A0