Installing the tower-to-rack kit, Tower-to-rack kit contents – Dell PowerEdge 2900 User Manual

Page 9

Advertising
background image

Tower-to-Rack Conversion Guide

7

Rack Stabilizer Feet

CAUTION:

Before installing systems in a rack, install front and side stabilizers on stand-alone racks or the front

stabilizer on racks joined to other racks. Failure to install stabilizers accordingly before installing systems in a
rack could cause the rack to tip over, potentially resulting in bodily injury under certain circumstances.
Therefore, always install the stabilizer(s) before installing components in the rack.

CAUTION:

After installing system/components in a rack, never pull more than one component out of the rack on

its slide assemblies at one time. The weight of more than one extended component could cause the rack to tip
over and may result in serious injury.

The stabilizer feet help prevent the rack from tipping over when a system or other component is pulled out
of the rack with the slide assemblies fully extended. See the documentation provided with the rack cabinet
for instructions on installing and anchoring the stabilizer feet.

Installing the Tower-to-Rack Kit

Tower-to-Rack Kit Contents

The tower-to-rack kit includes the following items (see Figure 1-1):

One rack front plate

One rack bezel, complete with keylock and keys

Two rack ears with rack handles and thumbscrews

Thirty-four M3 x 8 black flathead T10 Torx screws

Eight 6-32 x 0.188 black flathead Phillips screws

Six 10-32 shoulder nuts

One chassis metal filler panel

Three chassis plastic filler panels

Replacement label for the control panel display

book.book Page 7 Friday, May 26, 2006 3:03 PM