System error messages, System error messages -5, Table 3-3 – Dell Latitude Cpi User Manual

Page 31: 6\vwhp(uuru0hvvdjhv

Advertising
background image

System Error Messages

3-5

6\VWHP(UURU0HVVDJHV

The following table lists (in alphabetical order) system error messages that
may appear on the display during the boot routine or during normal computer
operation.

7DEOH  6\VWHP (UURU 0HVVDJHV

0HVVDJH

'HILQLWLRQ

3UREDEOH &DXVHV

Auxiliary device
failure

Integrated touch pad or
external PS/2 mouse
failed.

Integrated touch pad
or external PS/2
mouse faulty.

Bad command or
File Name

Command entered does
not exist or is not in path-
name specified.

Bad command or
filename entered.

Cache disabled
due to failure

Microprocessor’s internal
cache memory failed.

System board faulty.

Data error

Diskette or hard-disk drive
cannot read the data.

Faulty diskette/tape
drive subsystem or
hard-disk drive
subsystem.

Decreasing
available memory

Informational message
indicating memory is fail-
ing (usually preceded by
memory error message).

One or more
DIMMs faulty or
improperly seated.

Disk C: failed
initialization

Hard-disk drive failed to
initialize.

Hard-disk drive
improperly seated in
modular bay.

Hard-disk drive
damaged.

System files miss-
ing or corrupted.

Diskette drive 0
seek failure

System cannot read dis-
kette in diskette drive.

Diskette faulty or
incorrectly inserted
in drive.

Diskette read
failure

System cannot read dis-
kette in diskette drive.

System Setup con-
tains incorrect
settings.

Diskette drive inter-
face loose or faulty.

Diskette drive faulty.

Diskette sub-
system reset
failed

Diskette subsystem failed
to respond to reset com-
mand from computer.

System board faulty.

Advertising