Dell PowerVault NX3600 User Manual

Page 44

Advertising
background image

Video

Video type

Integrated Matrox G200

Video memory

16 MB shared

Environmental

NOTE: For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.

Temperature

Operating

Continuous operation: 5 °C to 40 °C (41 °F to 104 °F) at 20% to
80% relative humidity (RH), with 26 °C maximum dew point. De-
rate maximum allowable dry bulb temperature at 1 °C/300 m
above 900 m (1 °F per 550 ft).

NOTE: For information on supported expanded operating
temperature range and configurations, see
support.dell.com/manuals.

Storage

–40 °C to 60 °C (–40 °F to 140 °F) with a maximum temperature
gradation of 20 °C per hour

Relative humidity

Operating

8% to 85% (noncondensing) with maximum humidity gradation
of 10% per hour

Storage

5% to 95% at a maximum wet bulb temperature of 38 °C (100.4
°F)

Maximum vibration

Operating

0.26 G

rms

(5 Hz to 350 Hz at 0.0002G2/Hz) in operational

orientation for 5 min (Maximum)

Storage

1.04 G

rms

at 2 Hz to 200 Hz for 15 min (all six sides tested)

Maximum shock

Operating

31 G half-sine shock +/-5% with pulse duration of 2.6 ms +/-10%
in the operational orientation (Maximum)

Storage

Six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the system)
of 30 G for up to 10 ms
Six consecutively executed shock pulses in the positive and

negative x, y, and z axes (one pulse on each side of the system)

of 32 G faired square wave pulse with velocity change at 270

inches/second (685 centimeters/second)

Altitude

Operating

–16 m to 3048 m (–50 ft to 10,000 ft)

NOTE: For altitudes above 2950 ft, the maximum operating
temperature is derated 1 ºF/550 ft.

44