Dell POWEREDGE M1000E User Manual

Page 27

Advertising
background image

Dell M8428-k Hardware Reference Manual

15

53-1001980-01

Connecting the switch to the fabric

2

1. If the switch module is in full fabric mode, continue with

step 2

and

step 3

. If the module is in

NPIV mode, go on to

step 4

.

2. Log onto the converged network switch through a Telnet connection, using the admin account.

3. Modify the domain ID if required using switch module CLI commands.

The default domain ID is 1. If the switch module is not powered on until after it is connected to
the fabric and the default domain ID is already in use, the domain ID for the new switch
module is automatically reset to a unique value. If the switch module is connected to the fabric
after it has been powered on and the default domain ID is already in use, the fabric segments.

To find the domain IDs that are currently in use, run the fabricShow command on another
converged network switch or switch in the fabric. Identify an unused domain ID.

a. Disable the converged network switch being configured using the switchDisable

command.

b. Enter the configure command at the root prompt.

The command prompts display sequentially. Enter a new value at the Domain prompt or
press Enter to accept the default value. The converged network switch now has a unique
domain ID and can join the fabric. Following is an example of command output.

Fabric parameters (yes, y, no, n): [no] y

Domain: (1..239) [2]

R_A_TOV: (4000..120000) [10000]

E_D_TOV: (1000..5000) [2000]

WAN_TOV: (0..30000) [0]

MAX_HOPS: (7..19) [7]

Data field size: (256..2112) [2112]

Sequence Level Switching: (0..1) [0]

Disable Device Probing: (0..1) [0]

Suppress Class F Traffic: (0..1) [0]

Per-frame Route Priority: (0..1) [0]

Long Distance Fabric: (0..1) [0]

BB credit: (1..27) [16]

Disable FID Check (yes, y, no, n): [no]

Insistent Domain ID Mode (yes, y, no, n): [no]

Configure edge hold time (yes, y, no, n): [no]

Virtual Channel parameters (yes, y, no, n): [no]

F-Port login parameters (yes, y, no, n): [no]

Zoning Operation parameters (yes, y, no, n): [no]

RSCN Transmission Mode (yes, y, no, n): [no]

Arbitrated Loop parameters (yes, y, no, n): [no]

System services (yes, y, no, n): [no]

Portlog events enable (yes, y, no, n): [no]

ssl attributes (yes, y, no, n): [no]

rpcd attributes (yes, y, no, n): [no]

cfgload attributes (yes, y, no, n): [no]

webtools attributes (yes, y, no, n): [no]

Custom attributes (yes, y, no, n): [no]

system attributes (yes, y, no, n): [no]

System (yes, y, no, n): [no]

WARNING: The domain ID will be changed. The port level zoning may be

affected

c. Re-enable the switch module by entering the switchEnable command.

Advertising