Dell M8428-k Hardware Reference Manual

53-1001980-01

Connecting the switch to the fabric

2

NOTE

It could take a short time (typically a few seconds, but sometimes up to 20 seconds) for the
newly added switch module to appear in the fabric display with its newly assigned domain ID.

4. If you need to install transceivers, install them in the external CEE and FC ports as required.

a. Remove the dust plugs from the ports to be used.

b. If necessary, remove the end caps from the transceiver.

c. Orient the transceiver correctly and insert it into a port until it is firmly seated and the

latching mechanism clicks.

For instructions specific to the type of transceiver, refer to the transceiver manufacturer’s
documentation.

d. Repeat substeps a, b, and c for the remaining ports, as required.

NOTE

Use only Dell-approved transceivers in the external optical ports of this module.

5. Connect the cables to the transceivers.

The transceivers are keyed to ensure correct orientation. If a transceiver does not install easily,
ensure that it is correctly oriented and that the end caps have been removed. The cables used
in trunking groups must meet specific requirements.

ATTENTION

A cable should not be bent to a radius less than 5.08 cm (2 inches) under full tensile load and 3.048
cm (1.2 inches) with no tensile load.

Tie wraps are not recommended for optical cables because they are easily overtightened.

a. Orient a cable connector so that the key (the ridge on one side of connector) aligns with

the slot in the transceiver.

b. Insert the cable into the transceiver until the latching mechanism clicks. For instructions

specific to cable type, refer to the cable manufacturer’s documentation.

c. Repeat for the remaining transceivers as required.

6. Check the LEDs to verify that all components are functional.

For information about LED patterns, see the

“Interpreting LED activity”

on page 23.

7. Verify the correct operation of the converged network switch by typing the switchShow

command from the workstation.

This command provides information about switch module and port status.

8. Verify the correct operation of the converged network switch in the fabric by entering one of the

following commands:

a. If you are in NPIV mode, enter the ag --show command

b. If you are in full fabric mode, enter the fabricShow command

9. Back up the switch module configuration to an FTP server. See

“Backing up the configuration”

on page 20 for specifics.