Dell PowerEdge 1750 User Manual

Page 25

Advertising
background image

initialization failure

RAC. If the problem persists, you may need to replace the
system board. See "

Getting Help

."

 Gate A20 failure

Faulty keyboard controller (defective
system board).

Replace the system board. See "

Getting Help

."

 General failure

Application program or operating system
failure.

Reboot. If the message reappears, see your software
documentation.

 Hard disk controller failure

 Hard disk read failure

Incorrect configuration settings in the
System Setup program, improperly
connected hard drive, or faulty hard-
drive controller subsystem (defective
system board).

Check the hard-drive configuration settings in the System
Setup program. See "Using the System Setup Program" in the
User's Guide. Reinstall the hard drive. See "

Installing SCSI

Hard Drives

" in "Installing Drives."

 Invalid configuration information - please

run SETUP program.

Incorrect configuration settings in the
System Setup program, the NVRAM_CLR
jumper is installed, or the system
battery is faulty.

Check the System Setup configuration settings. See "Using
the System Setup Program" in the User's Guide. Remove the
NVRAM_CLR jumper. See

Figure A

-2

for jumper location.

Replace the battery. See "

Replacing the System Battery

" in

"Installing System Options."

 Invalid memory configuration detected.

Potential for data corruption exists!

Memory modules are not installed in
matched pairs.

Install memory modules in matched pairs. See "

Installing

Memory Modules

" in "Installing System Options."

 Invalid NVRAM configuration, resource re-

allocated

System configuration data has been
ignored.

Check the System Setup configuration settings. See "Using
the System Setup Program" in the User's Guide.

 I/O card parity interrupt at address

Expansion card(s) is improperly installed
or faulty.

Reinstall the expansion card(s). See "

Installing Expansion

Cards

" in "Installing System Options." If the problem persists,

replace the expansion card(s).

 Keyboard controller failure

Defective keyboard/mouse controller
(defective system board).

Replace the system board. See "

Getting Help

."

 Keyboard data line failure

 Keyboard stuck key failure

 Keyboard clock line failure

 Keyboard failure

Keyboard cable connector is loose or
improperly connected; defective
keyboard; defective keyboard/mouse
controller (defective system board).

Check the keyboard cable connection. Replace the keyboard.
If the problem persists, replace the system board. See
"

Getting Help

."

 Memory allocation error

Memory module(s) is not connected
properly, or an application program or
the operating system failed.

Reseat the modules. See "

Installing Memory Modules

" in

"Installing System Options." Reboot the system. If the
message reappears, see your software documentation.

 Memory address line failure at address, read

value expecting value

 Memory high data line failure at start

address to end address

 Memory high address line failure at start

address to end address

 Memory double word logic failure at start

address to end address

 Memory double word logic failure at address,

read value expecting value

 Memory odd/even logic failure at start

address to end address

 Memory odd/even logic failure at address,

read value expecting value

 Memory write/read failure at address, read

value expecting value

 Memory write/read failure at start address to

end address

Faulty or improperly seated memory
modules or defective system board.

 

Remove and reseat the memory modules. See "

Installing

Memory Modules

" in "Installing System Options." If the

problem persists, replace the memory modules. If the problem
persists, see "

Getting Help

."

 Memory parity failure at start address to end

address

 Memory parity error at address

Improperly seated or faulty memory
modules.

Remove and reseat the memory modules. See "

Installing

Memory Modules

" in "Installing System Options." If the

problem persists, replace the memory modules. If the problem
persists, see "

Getting Help

."

 No boot device available

Faulty diskette, diskette/CD drive
subsystem, hard drive, or hard-drive
subsystem; no boot disk in drive A.

Replace the diskette or the hard drive. See "

Installing Drives

."

If the problem persists, replace the system board. See
"

Getting Help

."

 No boot sector on hard- disk

No operating system on the hard drive.

Check the hard-drive configuration settings in the System
Setup program. See "Using the System Setup Program" in the
User's Guide.

 No timer tick interrupt

Defective system board.

Replace the system board. See "

Getting Help

."

 No PXE-capable device available

<F12> was pressed during POST and no
PXE devices are detected.

Check the cables connected to the NICs. Check the
configuration settings in the System Setup program for the
NICs. See "Using the System Setup Program" in the User's
Guide
.

 Non-system disk or disk error

Faulty diskette, diskette drive
subsystem, or hard-drive subsystem.

Replace the diskette. Reseat all drives and reboot the
system. If the error message reappears, see "

Getting Help

."

 Not a boot diskette

No operating system on diskette.

Use a bootable diskette.

Advertising