Pg 4 – Cleveland Range OGS-10.10 User Manual

Page 76

Advertising
background image

5

With the combi in the Hot Air mode with time on the timer, the door closed and the

start switch is depressed
b

The front display will include a lighted bar under the Hot Air symbol

•

When the heat circuit is energized the heat symbol will be energized

•

The cooking mode symbol will be energized.

•

The time display will invert and begin to count down.

c

The fan circuit is energized by the Control Board (A10) transmitting and

receiving a signal from terminals 5,6,7 and 8 on connector X10 to terminals 3,4,5
and 6 of connector X28 on the Gas Board (A20)

d

The Gas board (A20) Transmits a signal from terminal 4 of connector X26 to the

Motor Drive.
•

The motor Drive Board sends a signal through the thermal switch in the motor

from Terminal 5 and receives on terminal 6

•

If the thermal switch is not open the Motor Drive Board (U10) sends 240

VAC 3 phase to the motor.

•

The motor reverses direction every 120 seconds with a 15 second coast.

•

NOTE: If the set temperature is less than 212 degrees F than fan will be

pulsed on for 2 seconds every 60 seconds after the cabinet set temp (B6).

e

Hot air heat circuit is energized

•

A signal is sent from terminal 2 of connector X24 on the Gas Board (A20) to

terminal 4 of connector X2 on the Hot Air Power Burner and Fan Control
(U20) selecting the set speed of the combustion blower.
◊

When this speed is attained the signal is sent from terminal 2 of connector

X2 on the Hot Air Power Burner and Fan Control (U20) to terminal 3 of
connector X24 on the Gas Board (A20)

•

A request for heat is sent from terminal 3 of connector X20 on the Gas Board

(A20) to terminal 10 on connector X1 on the Hot Air Control Module (N20)
◊

24 VAC is sent from terminal 2 of connector X2 on the Hot Air Control

Module (N20) to the hot surface igniter (R20).

◊

The gas valve is energized allowing gas and air into the burner chamber to

be ignited by the hot surface igniter.

◊

The Hot Air Burner Control Module (N20) senses at least 1.5 micro amps

DC from the flame sensor (P1) at terminal 3 of connector X2 and sends a
signal from terminal 2 of connector X1 to terminal 10 of connector X25
on the Gas Board (A20

69