Pg 2, Ladder di ag ra m, Cleveland range, llc – Cleveland Range OGS-10.10 User Manual

Page 88: P 1 fl am e se ns or -r20, Ga s bo ar d x2, Po we r bu rn er ho t ai r fa n co n tr o l -u20, A10: x 10, X3: -u21, Gm) -a2 0, N20 x2

Advertising
background image

HO
T S

URF

AC

E

1

2

-P

1

FL

AM
E

SE
NS
OR

-R20

1

2

SP

EE

D S

TE

AM

GE

NE

RA

TO

R

GROU

ND

STEA

M G

EN

ER

ATO

R

GA
S BO

AR
D

X2

:

GROU

ND H

OT AIR

1

PO
WE
R BU

RN
ER

HO
T AI

R

FA

N

CO
N

TR

O

L

-U20

3

X1:

5
4

1

2

C

O

N

TR

O

L BO
A

R

D

-A10:

X

10

1

R

E

S

ET

5

GN
D

6

Tx

D

_1

2V

R

xD

_1

2V

0V

DC
IN

2

X28

4

3

X3:

X3:

-U21

3

X2

:

3

1

21

3

5
4

2

1

X1:

2
3

X24

8

7

21

1

9

PWM

ST

EAM

G

EN

ER

ATO

R

SPEE

D HOT AI

R 1

PWM

HOT AI

R 1

(GM)

-A2
0

5

ALA

RM

H

OT AI

R 1

Hi-L

imit

-N20

X2

RE

SE

T AI

R H

EAT

/G

O

P

O

W

ER SU

PP
LY

1

2V

D

C

PHASE ( L

1 )

RESET

H

OT A

IR

1 (HL1)

RE

SE

T H

OT A

IR

1

HEAT RE

QUES

T HL1

GN
D

12

V

D

C

IN

1

X20

12V

L

N

90

-2

64

V

AC

X20

3

2

4

1

N

L1

Hi-L

imit

RESE

T A

IR

H

EAT

PHAS

E ( L1 )

8

9

10

11

12

X1

:

1

2

3

X2

RE

SE

T AIR

HEA

T/G

O

-B7.2

-B7.1

6-9

N

OT

USE

D

STEA

M G

EN

. FL

AM

E O

K

RE

SET S

TE

AM

G

EN

.

RE

SET S

TE

AM

G

EN

.

HE

AT RE

QU

ES

T (D

E)

ALA

RM

ST

EA

M GE

N.

ALA

RM

ST

EA

M GE

N. (

DE)

GND. FIR

IN

G A

UTO

MAT

HOT AIR 1

FLA

ME

OK

GND. FIRING

AU

TO

MAT

ALA

RM

H

OT AI

R 1

X25

X21

X25

10

X25

2

9

6

X21

X26

4
3
1

1

3
4

2

5

-U10:X1

2

11
9

X25

9

6

22

MO
TO
R DR

IV

E

21

22

21

-N21

7

Hi-L

im

it

PH

ASE

( L

1 )

Hi-L

im

it

RE

SE

T AIR

H

EAT

NEUT

RAL

FLAM

ECHECK

1

2

3

4

5

6

7

GND

X1

:

12

11

10
9
8

NEU

TR

AL

FLA

ME

CH

EC

K

65

4
3
2
1

GND

2

31

L1

N

12

0

L1

N

HOT S

URFA

C

E

IG
N

IT

O

R

-R21

0

24

0

24

24

VAC

24

VAC

120 V

AC

12

V

D

C

/7.C
5

/9.D
3

VA
LV

E

GAS

-P

2

FL

AM
E

SE
NS
OR

GAS

VA
LV

E

HO
T AI
R BU

RN
ER

CONTROL

MO
D

U

LE

ST

EA
M

BU
RN
ER

CONTROL

MO
D

U

LE

STE
A

M

PO
WE
R BU

RN
ER

FA

N

CO
N

TR

O

L

-G1

(C

ONTR

OL BOA

RD

)

/9.C

5

(-A10

:X

11:8)

TRA

NS

MIT

REC

IEV

E

12V

GND

F

E

D

C

B

A

1

2

3

4

5

6

7

8

F

E

D

C

B

A

1

2

3

4

5

6

7

8

CLEVELAND RANGE, LLC

1333 East 179th St., Cleveland, Ohio 44110-2574

VOLTAGE:

WATTAGE:

CURRENT:

DATE

SHEET OF

REV

DRAWN BY

DRAWING NO.

THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE.

THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE.

TITLE

SIZE

B

WIRING DIAGRAM

OGB 6.20/10.10

300493

120VAC

10.25W

11.7A

DRL

7-25-05

8

9

A

IG

NI

TE

R

LADDER DI

AG

RA
M

0V

-X10

:32

81

Advertising