In the full mode (3 drops in the display) the Y2 valve will be energized

continuously.

h

When the timer counts to 0 or the core temp probe (B10) reaches the set amount

the cycle ends and the steam generator reverts to the standby temperature of 190-
degree F.

6

With the combi in the Rethermalization mode with time on the timer, the door closed

and the start switch is depressed
a

The front display will include a lighted bar under the Retherm symbol

When the heat circuit is energized the heat symbol will be energized

The cooking mode symbol will be energized.

The time display will invert and begin to count down.

b

The fan circuit is energized by the Control Board (A10) transmitting and

receiving a signal from terminals 5,6,7 and 8 on connector X10 to terminals 3,4,5
and 6 of connector X28 on the Gas Board (A20)

c

The Gas board (A20) Transmits a signal from terminal 4 of connector X26 to the

Motor Drive.

The motor Drive Board sends a signal through the thermal switch in the motor

from Terminal 5 and receives on terminal 6

If the thermal switch is not open the Motor Drive Board (U10) sends 220

VAC 3 phase to the motor.

The motor reverses direction every 120 seconds with a 15 second coast.

NOTE: If the set temperature is less than 212 degrees F than fan will be

pulsed on for 2 seconds every 60 seconds after the cabinet set temp (B6).

d

The steam generator heat circuit is energized. Steam production takes precedence

in the Combi mode

A signal is sent from terminal 8 of connector X24 on the Gas Board (A20) to

terminal 4 of connector X2 on the Steam Power Burner and Fan Control
(U21) selecting the set speed of the combustion blower.

When this speed is attained the signal is sent from terminal 2 of connector

X2 on the Steam Power Burner and Fan Control (U21) to terminal 9 of
connector X24 on the Gas Board (A20)

A request for heat is sent from terminal 3 of connector X21 on the Gas Board

(A20) to terminal 10 on connector X1 on the Steam Burner Control Module
(N21)

24 VAC is sent from terminal 2 of connector X2 on the Steam Burner

Control Module (N21) to the hot surface igniter (R20).

The gas valve is energized allowing gas and air into the burner chamber to

be ignited by the hot surface igniter.

The Steam Burner Control Module (N21) senses at least 1.5 micro amps

DC from the flame sensor (P1) at terminal 3 of connector X2 and sends a
signal from terminal 2 of connector X1 to terminal 11 of connector X25
on the Gas Board (A20)

e

After the bypass probe (B5) is satisfied then the hot air heat circuit is energized to

increase the cabinet temperature to the setting.

72