SEQUENCE OF OPERATIONS

When using these instructions refer to the OGS 6.20/10.10 wiring schematic.

1

When 120 VAC is applied to the combi, it is sent through the line filter (Z1) to the

Power Control Switch (S1).

2

When the Power Control Switch (S1) is closed

a

The red light in the switch is energized.

b

120 VAC is sent through the 7 amp fuse (F10) to terminal 1 of connector X11 on

the Motor Drive (U10)

c

120vac is sent through the 2 amp fuse (F1.1) to

•

The primary of the Hot Air 24v Transformer (T1)

◊

24 VAC is sent from the secondary of the transformer to the Hot air

Burner Control (N20)

•

The primary of the Steam 24v Transformer (T2)

◊

24 VAC is sent from the secondary of the transformer to the Steam Burner

Control (N21)

•

To terminal 12 of connector X1 on the Hot Air Burner Control (N20)

•

To terminal 12 of connector X1 on the Steam Burner Control (N21)

•

The 12 VDC Power Supply (G1)

◊

12 VDC is sent to terminals 1 and 2 of connector X20 on the Gas Board

(A20)

◊

12 VDC is sent to terminal 3 and 4 of connector X10 on the Control Board

(A10)

•

To terminal 2 of connector X1 on the Hot Air Power Burner and Fan Control

(U20)

•

To terminal 2 of connector X1 on the Steam Power Burner and Fan Control

(U21)

•

To terminal 1 of connector X12 on the Control Board (A10)

d

With 120 VAC to the Control Board (A10) The Operation Board (A11) is

energized
•

An alarm will sound for one second

•

All the LED’s and the display will energize one at a time.

•

“STARTING” will be displayed for 3 seconds

•

“Please wait” will be displayed

•

The international model number will be displayed

•

The time and date will be displayed and this will continue until the on/off

switch is depressed.

3

When the ON/OFF is depressed with the combi in the steam mode

a

The display will show the set temperature and set time.

4

With the combi in the steam mode with time on the timer, the door closed and the

start switch is depressed
a

The front display will include a lighted bar under the steam symbol

83

Advertising
This manual is related to the following products: