4 . Check and replace any damaged

o-rings and seals . O-rings and seals
can be wiped clean but not soaked
in solvent .

5 . Unscrew packing nuts and replace

the packing ONLY if a leak will not
stop when the nut is tightened (See
Figure 5) . Do not over-tighten a
packing nut because this will restrict
movement of the needle .

6 . Re-assemble in reverse order of

above and use a non-silicone oil on
moving parts . Apply Vaseline® or
light grease on threaded joints and
hose connections .

TECHNICAL SERvICE
Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding
the operation or repair of this tool or
for additional copies of this manual .

TOOL REPAIR
Only qualified personnel should repair
the tool and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently .

STORAGE
1 . When not using spray gun,

turn the fluid adjustment knob
counterclockwise to open which
will reduce spring tension on needle
fluid tip .

2 . Spray gun mUST BE well cleaned

and lightly lubricated .

Troubleshooting Chart

Stop using tool immediately if any of the following problems occur. Serious personal injury could occur.

Any repairs or replacements must be done by a Qualified Service Person or Authorized Service Center.

Symptom

Possible Cause(s)

Corrective Action

Right or left
heavy spray
pattern

1 . Holes in left or right side of the air cap

are plugged

1 . Clean . Use only non-metallic pick

2 . Dirt on left or right side of fluid tip

2 . Clean

Top or
bottom
heavy spray
pattern

1 . Dried material at top or bottom of fluid

tip

1 . Clean

2 . Loose air cap or dirty seat

2 . Clean and tighten

3 . Air cap plugged

3 . Clean . Use only non-metallic pick

Split spray
pattern

1 . Fan pattern open too far

1 . Partially close the pattern adjustment

2 . Fluid turned in too far

2 . Increase fluid

3 . Atomization air too high

3 . Reduce atomization air pressure

Center
heavy spray
pattern

1 . Fan adjustment partially closed

1 . Open fan pattern adjustment

2 . Material too thick

2 . Thin to proper viscosity

3 . Atomization pressure too low

3 . Increase atomization pressure

Sputtering
spray

1 . Material level too low

1 . Refill

2 . Container tipped too far

2 . Hold more upright

3 . Loose fluid inlet connection

3 . Tighten

4 . Loose or damaged fluid tip / seat

4 . Adjust or replace

5 . Dry or loose fluid needle packing nut

5 . Lubricate and or tighten

6 . Air vent clogged

6 . Clear vent hole

Fluid leaking from packing
nut

1 . Packing nut loose

1 . Tighten, but do not restrict needle

2 . Packing worn or dry

2 . Replace or lubricate (non-silicone oil)