Operating Instructions

Gravity Feed Spray Gun

7

www.chpower.com

Troubleshooting Chart (Continued)

Stop using tool immediately if any of the following problems occur. Serious personal injury could occur.

Any repairs or replacements must be done by a Qualified Service Person or Authorized Service Center.

Symptom

Possible Cause(s)

Corrective Action

Air leaking from air cap
without pulling trigger

1 . Sticking air valve stem

1 . Lubricate

2 . Contaminate on air valve or seat

2 . Clean

3 . Worn or damaged air valve or seat

3 . Replace

4 . Broken air valve spring

4 . Replace

5 . Bent valve stem

5 . Replace

Fluid leaking from fluid tip
of pressure feed spray gun

1 . Packing nut too tight

1 . Adjust

2 . Fluid tip worn or damaged

2 . Replace tip and/or needle

3 . Foreign matter on tip

3 . Clean

4 . Fluid needle spring broken

4 . Replace

Excessive overspray

1 . Too high atomization pressure

1 . Reduce pressure

2 . Too far from work surface

2 . Adjust to proper distance

3 . Improper stroking (arcing, gun motion

too fast)

3 . Move at moderate pace, parallel to surface

Will not spray

1 . No pressure at gun

1 . Check air lines

2 . Fluid control not open enough

2 . Open fluid control

3 . Fluid too heavy

3 . Thin fluid or change to pressure feed system