Cortelco CALLER ID TYPE II 2700 User Manual

Page 11

Advertising
background image

11

6.

When [FLASH TIMER (MS)] appears, press REVIEW UP to toggle
between 600ms, 100 ms, and 300ms. After selecting the desired
flash time, press MENU to confirm selection.

7.

When [RINGER CADENCE] appears, the default setting is 3. To
alter this setting,

press REVIEW UP. There are 10 ringer

cadences and each one will be played as you scroll through them.
After the desired ringer cadence is displayed, press MENU to
confirm selection.

8.

When [RINGER VOLUME] appears, the default setting is 5. To
alter the

ringer volume, press REVIEW UP. There are 7 ringer

volume levels and each one will be played as you scroll through
them. To turn the ringer off, select [OFF] in the Menu. After the
desired ringer volume level is displayed, press MENU to confirm
selection.

9.

When [VOICEMAIL NUMBER] appears, enter the voicemail number
(maximum of 18 digits) using the keypad. To delete a number or
digit, press REVIEW DOWN to erase the number(s). After the
desired number has been entered, press MENU to confirm selec-
tion.

10. When [#3 SEC PAUSES] appears, enter the desired number of

pauses using the keypad. After the desired setting has been
entered, press MENU to confirm selection.

11. When [VM PASSWORD] appears, enter the desired password using

the keypad (maximum of 5 digits). To delete a number or digit,
press REVIEW DOWN to erase the number(s). After the desired
number has been entered, press MENU to confirm selection.

12. When [HOLD MODE] appears on the display. Press REVIEW UP to

select either NORMAL or PBX. In NORMAL mode, the HOLD button
activates a local hold function. This can be released at any parallel
phone. In PBX mode, the HOLD button dials a code which places a
PBX line on hold. If you select PBX mode, see Step 15 to program
the code.

13. When [RELEASE MODE] appears on the display. Press REVIEW

UP to select either NEWCALL or HANGUP. In NEWCALL mode, the
RELEASE button provides a 1.5 second line break. This will
ensure that the line is clear and a new call can be dialed. In
HANGUP mode, the RELEASE button drops the line and a new
connection is not made. This is primarily intended for program-
ming into speed dial locations.

14. When [SDT TIME] appears on the display, press REVIEW UP to

change Stutter Dial Tone timing. Please note that the default
setting of 1700 mSec is correct for most applications.

15. This only applies if you have selected PBX HOLD mode.

a.

Press SAVE. The display shows [SAVE TO ?]

b.

Press HOLD. The display shows [ENTER NUMBER >]

c.

Dial the code using the keypad.

d.

Press SAVE.

Advertising