5

dedicated sensor wires may be used for its connection. Details are provided in

sensor instructions.

Remote Indoor Temperature Sensor

A remote temperature sensor may be used with the programmable heat pump

and programmable air conditioner thermostats where it is desirable to install the

thermostat in a limited access location while measuring the temperature in the

living space. The remote room sensor may be used as a stand alone or average

with local sensor.

Two−Piece Thermostat Configuration

The Performance Series AC/HP Control can be installed in one of two

configurations. The control may be installed as a single−piece thermostat or it

may be split into two pieces and mounted in separate locations. As a single−piece

unit, all required wiring must be brought to the Equipment Control Module for

connection to the terminal strip. In two−piece configuration, the Display Module

can be mounted in the living space while the Equipment Control Module may be

mounted near the indoor furnace or fan coil. Connection from the display to the

Equipment Control Module requires only two wires. All other control wires are

connected to the Equipment Control Module from the HVAC equipment. This

configuration results in a slimmer display and locates the Equipment Control

Module containing the switching relays away from the main living space where

relay clicking will not be heard.
The model numbers on the Display Module and the Equipment Control Module

(ECM) must match or unpredictable results may occur.
Two−wire pigtail replacement part number is TX−2WR−05.