Gas conversion (to l.p.g. or natural gas), A) replacement of the oven burner injector – CDA SC309 User Manual

Page 10

Advertising
background image

Gas conversion (to L.P.G. or Natural gas)

This appliance is regulated to work with
the gas indicated in the gas regulation
label.

If it has to work with another type of
gas (L.P.G. or Natural gas), before the
appliance is connected you must
substitute the oven and grill burner
injectors as follows:

a) REPLACEMENT OF THE

OVEN BURNER INJECTOR

Open the oven door completely.

Remove the burner cover (Fig. 5).

Remove the burner by unscrewing
the two front screws (Fig. 6). Take
care not to damage the wire to the
ignition electrode and the safety
valve probe.

Unscrew the oven burner injector
(Fig. 7) using a 7 mm spanner and
substitute it with one (see table) of
the correct size.

Replace all the components by fol
lowing in reverse the operations
explained above.

Figure 5

Figure 6

Figure 7

10