Lighting of oven burner – CDA SC309 User Manual

Page 17

Advertising
background image

LIGHTING OF OVEN BURNER

The thermostatic tap controlling the gas supply to the burner is equipped with a safety
device which automatically stops the gas flow in case of flame extinction. The tempera-
ture is constantly maintained on the set value.
The electric ignition starts up by pressing the thermostat knob.

A safety device prevents the electric ignition from functioning when the oven
door is shut.

To light the burner, you need to:

1 – Fully open the oven door.

2 – Press the thermostat knob (fig. 16) thoroughly to start up the electric ignition and,

keeping the knob under pressure turn it anti-clockwise (fig. 18) to position

Never continue this operation for more than 15 seconds. If the burner has still not
ignited, wait for about 1 minute prior to repeating the ignition.

To light the oven manually, approach a flame to the hole “A” of the floor (fig. 19),
then press and turn the thermostat knob.

3 – Wait about ten seconds after lighting the burner to release the knob (priming time

of the thermocouple)

4 – Adjust the thermostat knob on the desired setting.

If the flame extinguishes for any reason, the safety valve will automatically shut off the
gas supply to the burner.
To re-light the burner, first turn the oven control knob to position

●, wait for at least 1

minute and then repeat the lighting procedure.

For a correct pre-heating, we suggest to remove tray and shelf from the oven and
introduce them again after 15 minutes.

ATTENTION: In case of manual lighting, never turn the thermostat tap before
approaching a flame to the hole “A” of the floor.

A

Figure 18

Figure 19

17