Static pressure reading location diagrams – Carrier 58MVP User Manual

Page 42

Advertising
background image

Downflow Total Static Pressure Reading Locations

A95091

Closet — Downflow Application

ELECTRONIC

AIR CLEANER

HUMIDIFIER

A/C COIL

VENT

COMBUSTION
AIR

OUTDOOR
UNIT

AIRFLOW

RETURN STATIC

INCLINE MANOMETER

SUPPLY STATIC

INCLINE MANOMETER

Upflow Total Static Pressure Reading Locations

A95090

Basement — Upflow Application

COMBUSTION
AIR PIPE

A/C COIL

OUTDOOR UNIT

VENT PIPE

HUMIDIFIER

GAS-FIRED
WATER HEATER

ELECTRONIC
AIR CLEANER

AIRFLOW

SUPPLY STATIC

INCLINE MANOMETER

RETURN STATIC

INCLINE MANOMETER