Replacing of the lamp

When replacing the lamp, be sure to disconnect the electric
cord from the power supply.

1

Remove the lamp-house cover by holding the upper

I part and pull it towards you.

O Slightly press the lamp and turn it counter-clockwise as
^ far as it will go, then pull it out.

3

Face the front of the new lamp and insert it fitting the

holes to the socket guides, and turn it clockwise.

Set the lamp-house cover after the lower part of the
cover has been inserted.

Note : When the lamp is replaced, the light center posi­

tion changes and there may be a slight unevenness in the

brightness of the picture. In this case, loosen the two

position adjusting screws of the lamp socket and adjust

the position of the lamp by moving it to right or left.
Then tighten the screws.

Cleaning

The lens can be taken out while pulling the focusing knob
towards you. Remove dust lightly with either a lens brush
or silicon cloth. To clean the film gate, remove the

pressure plate. First, protrude the zoom lens to the
maximum extension by turning the focusing knob. Pull

the pressure plate towards the lens, then towards you.

Remove the dust lightly with the brush separately supplied.