Installation

B Installation

How to Install the Unit

1)

To prevent vibration and noise, make sure the unit

is installed securely and firmly

Install the unit where the sunlight does not shine

directly on the unit.

3) The outside of the cabinet must extend outward for

at least 12" and there should be no obstacles, such

as a fence or wall, within 20" from the back of the
cabinet because it will prevent heat radiation of the
condenser.

Restriction of outside air will greatly reduce the

cooling efficiency of the air conditioner.

Fence

CAUTION: All side louvers of the cabinet must remain exposed to the outside of the

_ structure.

^ Install the unit a little slanted so the back is slightly lower than the front (about 1/2").

This will force condensed water to flow to the outside.

5

)

Install the unit with the bottom about 30"~60" above the floor level.

Window Requirements

: All supporting parts should be secured to firm wood, masonry, or metal.

• This unit is designed for Installation In standard double

hung windows with actual opening widths from 27"

to 39".

■ The top and bottom window sash must open sufficiently

to allow a clear vertical opening of 16" from the bottom

of the upper sash to the window stool.