Communication, Error codes – Salter Brecknell 6712 User Manual

Page 18

Advertising
background image

Model 6712 Point-of-Sale Interface Scale User’s Manual

18

Communication

DE-9 Female Scale

DE-9 Male Host

Pin Name Direction

Pin

Name

Direction

1.

JMP1

-

1.

DCD

IN

2.

TXD

OUT

2.

RXD

IN

3.

RXD

IN

3.

TXD

OUT

4.

JMP 1

-

4.

DTR

OUT

5.

GND

REF

5.

GND

-

6.

JMP 1

-

6.

DSR

IN

7.

JMP 2

-

7.

RTS

OUT

8.

JMP 2

-

8.

CTS

IN

9.

NC

-

9.

RI

IN

NOTE: JMP1 PINS 1, 4 and 6, and JMP 2 Pins 7
and 8 are internally jumpered inside the scale.

Error Codes

Any system errors detected by the scale will be
displayed as the letter E followed by a one-digit
error code. Press the TEST key to continue
operation. If a calibration error occurs, the only
way to clear the error is by recalibrating the unit.

The error codes are defined as follows:

Err-1

Calibration Error

Err-2

Configuration Error

Err-3

Initial Zero Error

Err-4

Zero Error

See the troubleshooting section at the end of this
manual.

The NCI 6712 comes factory configured as a
serial RS-232 interface device. There is one 9-
pin DE type female connector accessible at the
rear of the unit. The functional pinout of this
cable provided with your scale is that of a stan-
dard PC, which is as follows: