Troubleshooting – Salter Brecknell 6712 User Manual

Page 20

Advertising
background image

Model 6712 Point-of-Sale Interface Scale User’s Manual

20

Troubleshooting

Perform each step in sequence to correct the
error condition. If the problem cannot be cor-
rected, contact your local Weigh-Tronix dealer.

No power (display is blank)
1. Check that the primary side of the cord is

plugged into the AC outlet, and the second-
ary side is properly connected to the power
jack on the back of the scale.

2. Replace power supply.
3. Replace the display board.
4. Replace the main board.

Missing or extra segments on display
1. Replace display board.
2. Replace the main board.

Scale will not return to zero, or incorrect

weight is displayed

1. Press the ZERO key.
2. Check for interference of weighing platform.
3. Power down, then power up the scale.
4. Recalibrate the scale.
5. Replace the load cell.
6. Replace the main board.

Display shows unrecognized characters
1. Check software PROM for proper insertion.
2. Check display cables for the proper connec-

tion.

3. Replace PROM
4. Replace the display board.
5. Replace the main board.

Display shows under “_ _ _” dashes

(Indicates that the scale is below zero or under capacity.)

1. Verify that the weigh platter is on the scale.
2. Press the ZERO key.
3. Power down, remove any items from the

platter, and then power up the scale.

4. Recalibrate the scale.
5. Replace the load cell.

Symptom and
Recommended Action