Magnetic door stop, Door panel, Aligning / securing verticals – Coral Industries 6000 Neo-Angle Swing Door (Traditional) - 846 User Manual
Page 6
846-GP 12/05
Adjust side panels, corner posts, and door
stops until magnetic strip aligns properly on
door panel and door closes evenly at top
and bottom.
Once desired alignment of parts has been
achieved, from inside shower, drill four
evenly spaced holes through leg of jamb
(1/4" from edge) into side panels. Secure
using 8A x 3/8" truss head screws (J).
Secure corner posts to side panels and
door stops in same manner, by drilling from
inside shower, four evenly spaced holes
through leg of corner post (1/4" from edge)
into side panels and into hinge and
magnetic door stops. Attach using 8A x 3/8"
truss head screws (J).
Jamb
Side Panel
INSIDE OF SHOWER
Magnetic
Door Stop
Corner
Post
Sill
A
B
8A x 3/8"
Truss Head
Screws
J
1/4"
1/4"
1/4"
Slide magnetic strip (I) into slot on
magnetic door stop (H). Trim ends even
with door stop using scissors.
Decide which will be the opening side of
your door. Door is normally installed to
open on the side of unit nearest to the
showerhead. For safety purposes, door
should be installed to open out from
shower.
Slide magnetic door stop into corner post
on opening side of door with magnetic strip
facing outside of shower.
Position hinge door stop, which is attached
to door panel, into opposite corner post.
Magnetic
Strip
When mounting corner posts and
jambs to side panels, do not drill
through front side of panel or hit
glass with drill bit. Glass is seated
approximately 1/2" into channel.
Magnetic
Door
Stop
Corner
Post
Side
Panel
Sill
A
Door Panel
with Hinge
Door Stop
attached
OUTSIDE OF SHOWER
D
Side
Panel
H
I
If magnetic strips do not seal tightly,
reverse polarity by removing strip
from door stop and replacing it with
the previous top end as the bottom
end.
Corner
Post
D
D
H
7
Magnetic Door Stop
(H) /
Door Panel
8
Aligning / Securing
Verticals