Kb c, Ke a, Securing verticals – Coral Industries Steam Swing Door/DPNL - 5S3 User Manual
Page 7: Pull handle kit

5S3-GP 10/07
Adjust side panels, magnetic door stop, and hinge door stop
until magnetic strip aligns properly on door panel and door
closes evenly at top and bottom. Once desired alignment of
parts has been achieved, from inside shower, drill four
evenly spaced holes through legs of jambs (1/4" from edge)
into side panels. Secure using 8A x 3/8" truss head screws
(K).
Secure hinge and magnetic door stops to side panels in the
same manner, by drilling, from inside shower, four evenly
spaced holes (1/4" from edge of door stops) through door
stops into side panels. Secure using 8A x 3/8" truss head
screws.
Secure header by drilling, from inside shower, through
header into jambs, hinge and magnetic door stops. Secure
using 8A x 3/8" truss head screws.
When securing door stops and jambs to side panels,
do not drill through front side of panel or hit glass with
drill bit. Glass is seated approximately 1/2" into
channel.
Hinge or
Magnetic
Door Stop
Jamb
Door
Panel
Header
Side Panel
8A x 3/8"
Truss Head
Screws
K
B
C
1/4"
1/4"
INSIDE OF SHOWER
1/4"
1/4"
Hinge
Door Stop
8A x 3/8 "
Truss Head Screws
K
E
A
Side
Panel
Secure sill by drilling, from outside shower, through sill into
magnetic door stop and hinge stop. Secure using 8A x 3/8"
truss head screw.
OUTSIDE OF SHOWER
Sill
11
Securing Verticals
Magnetic
Door Stop
Side
Panel
Door
Panel
10
Securing Verticals
6-32 x 1 1/4"
Pan Head
Screw
Interior
Handle
Exterior
Handle
OUTSIDE OF SHOWER
Pull
Handle
Kit
Handle for your door may be pre-installed. If so,
disregard this step and continue installation.
M
Mount pull handles, from pull handle kit (L), using
6-32 x 1 1/4" pan head screws provided. Screw heads
should be on the inside of shower.
12
Pull Handle Kit
(M)