Detex Electric Integration User Manual

Owner's copy, Rim ei - electric integration, Jewelers (small) screwdriver tools required

Advertising
background image

®

Jewelers (Small) Screwdriver

Tools Required

Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045

(830)629-2900 / 1-800-729-3839 / Fax (830)620-6711

E-MAIL: [email protected] INTERNET: www.detex.com

104875 December 14, 2011

INSTALLATION INSTRUCTIONS FOR

ADVANTEX / VALUE SERIES RIM EI PRODUCT

Owner's Copy

Authorized Access switch is activated by outside lever trim

Activation of the pushpad will transfer switch contact.

LBM (latch bolt monitor) in series with pushpad switch.

KEY SWITCH common 12 to 24 volts DC, 500ma

GROUND (-) common to Green, Red, and siren

GROUND (-) common to Green, Red, and siren

PushPad/LBM monitors the pushpad and the deadlocking actuator in the latchbolt.

move the appropriate jumper on the circuit board.

To select Open or Closed switch orientation,

GND

GND

*JUMPER

EI CIRCUIT SCHEMATIC

Theory of Operation:

Jumpers

*

GREEN LED (+) 12 to 24 volts DC, 10ma max

KEY SWITCH normally open contact
KEY SWITCH normally closed contact

SIREN (+) 12 to 24 volts DC, 110ma max

RED LED (+) 12 to 24 volts DC, 10ma max

Terminal

8

11
12

10

9

3, 4

5
6

*

7

1, 2

No.

*

Red wire

Comments

SIREN

GREEN

NO

NC

KEY

NC

GND

RED

*JUMPER

NO

*

PushPad/LBM

Switch

Switch

Authorized Access

CUSTOMER WIRING

Key Switch

12 (-)

4 COMMON

10 OPEN

9 COMMON

7 (+) SIREN

11 CLOSED

2 COMMON

1 *OPEN/CLOSED

3 *OPEN/CLOSED

5 (+) GREEN LED
6 (+) RED LED

8 (-)

Call customer service for replacement part number

EI Fillerplate Subassembly p/n 101783-X

Rim EI - Electric Integration

Dwg #: 101379 Advantex (SS)

104600 Advantex (AL)

101800 Value Series

&

Door Closed - Deadlocking actuator activates PushPad/LBM (Latch Bolt Monitoring) Switch. Authorized Access Switch is not affected.

Door Closed - Depressing PushPad changes the state of the PushPad/LBM Switch. Authorized Access Switch is not affected.

Door Closed - Authorized (Auth) Access Switch is activated by operating outside trim. As the latchbolt begins to retract, the

PushPad/LBM Switch is also activated.

EI PWA

p/n 101782

PRECAUTIONARY NOTE:

Be careful when installing filler plate assembly not to damage ribbon cable.