Detex VRA-143-D User Manual

Detex Safety

Advertising
background image

Detex Corp, 302 Detex Drive, New Braunfels, Texas 78130 (830)629-2900/1-800-729-3839/ FAX(830)620-6711

E-Mail: [email protected] Internet: www.detex.com

FIGURE 2, TYPE C

Either leaf opens first.

Strike plate installed on VRA door.

Lock on leaf without VRA must be

ECL-230.

FIGURE 1, TYPE B

Active leaf opens both doors.

Overlap plates installed on the inac-

tive leaf.

FIGURE 3, TYPE D

Each leaf is independent.

GENERAL INFORMATION

The VRA-143 vertical rod assembly

is designed for use on double doors

in conjunction with the following

Detex product:

Exit Control Lock Model ECL-

230D.

NOTE

To locate the mounting holes for the

ECL-230's and the VRA, use the tem-

plates provided with these instruc-

tions and disregard the templates

provided with the ECL-230's.

The ECL-230's and the VRA can

be used in any of the three arrange-

ments shown .

Outside Key Control (OKC)

An OKC can be used on the active

leaf of a type 'C' installation.

An OKC can also be used on a type

'B' or type 'D' installation but for

entry only.

INSTALLATION INSTRUCTIONS FOR VERTICAL ROD ASSEMBLY, MODEL VRA-143

DETEX INS143 PAGE 1

FIGURE 4

TOOLS AND SUPPLIES RE-

QUIRED

Center punch to mark hole centers

Hammer

Drill motor and bits

Tape to fasten templates

Tape measure

Screwdriver, blade type

7/8" diameter drill

1" diameter drill

#10-24 tap

EQUIVALENT METRIC

DIMENSIONS

INCHES MILLIMETERS

0.150

4

0.152

4

1/4

6

3/4

19

1

25

1-1/4

32

INS-143/PM April 20, 2007

Advertising