CHANGING THE POSITION OF THE

RELEASE BOLT

Remove the cover. (An Allen wrench is provide for this

purpose.)

Note the cross-bar in the case. It is held in place by two

screws and a plate at each end. Remove the screws and

plate at one end only and remove the bar.

Remove the release bolt and install it in the opposite

hole.

Do not install the bar at his time.

INSTALLATION

Templates are provided for installation on either door,

left or right. Select the proper template and follow the

instructions on the template for door and frame prepa-

ration.

Install the retainer plate on the frame and the strike

plate on the active door. Use two flat head screws for

each plate.

Remove the cover from the DDH and remove the cross-

bar in the base.

Open the doors and install the base on the inactive door

with five pan-head screws.

Install the cross-bar in the base and remove the pin

holding the locking bolt.

Install the cover.

FIGURE 1.- TYPICAL INSTALLATION

NOTE

The DDH-2250 is shipped for installation on the right

hand door, as shown in figure 1. If the right-hand door

is to be the active leaf, change the bolt position in the

DDH as described below and install it on the left-hand

door.

ADDITIONAL HARDWARE REQUIREMENTS

A double-door strike is required.

For the Detex ECL-230D, use the Detex ECL-435K

strike.

OPERATION

The inactive leaf must close first. When the active door

is closed, the release bolt on the back of the DDH hits

the strike plate on the door and pushes the locking bolt

into the retaining plate on the door frame.

PROBLEMS?

Contact Customer Service at

1-800-729-3839