EFCO CORPORATION 7/2012 PART NO. Y306
Page 18 of 28
Series 5600 Silicone Structural Glazed Installation Instructions
Section VI: Glazing Preparation
Installation of Spandrel Glazing Adaptors
Center Tongue
X
Exterior
Dense Preset
GLAZING
X
X
1/4"
1"
Glazing
Horizontal Adaptors
Deep Pocket
Shallow Pocket
X
X
X
X
Sponge Preset
Interior
Vertical Adaptor Cut Length
Without Expansion Joint
= D.L.O. + 1”
Vertical Adaptor Cut Length
With Expansion Joint; See
“APPROVED” Shop Drawings
Set all adaptors in a
continuous bead of sealant.
Attach vertical adaptor to
mullion with #8 X 1 ¼”
FHSMS Stainless Steel screw
at a minimum 18” O.C.
(Seal heads w/ silicone.)
Vertical Adaptor
Horizontal Adaptor
Horizontal Adaptor Cut
Length = D.L.O. – 1/16”