EFCO S5600 Structural Glazed User Manual
Page 9
Advertising

EFCO CORPORATION 7/2012 PART NO. Y306
Page 9 of 28
Series 5600 Silicone Structural Glazed Installation Instructions
Section V: Frame Assembly
Step #2 Install Frame Components
A.)
Refer to the approved shop drawings for job conditions. Install assembled frames
according to the approved shop drawings.
Concealed Fastener
Exposed Fastener
#8 X 5/8” FH SMS
Note: Shear block must be leveled
and perpendicular to the vertical.
Note: Screws should be torqued to full
tightness after leveling shear block.
#10 X 3/4” PH SMS
#14 X 1/2” HWH SMS
#14 X 1/2” HWH SMS
Level
Shear Block
Note: Fasten in hidden
location where possible.
(Top of horizontal at
ceiling, below horizontal
at stool.)
Advertising