Fig. 18, Step 3), Intermediate horizontal – EFCO 904 Series User Manual

Page 25: Hcw6, Fig. 17, Fig. 16, Step 1)

Advertising
background image

WEEP

DPS 7/2001

AMOUNT of SILICONE TYPE SEALANT.

APPLY BAFFLES WITH a SMALL

on center or 2 per lite at quarter points. Install weep baffles

Drill 1/4" diameter weep holes in the horizontal face member at 48"

over holes with silicone. Do not plug weep holes with silicone.

[FIG. 18]

See Fig. 18 above.

STEP 3)

HOLES

8499 SIMILAR

9565 SHOWN

(CONT.)

PAGE 23

D.L.O.

INTERMEDIATE HORIZONTAL

3/8"

INTERIOR

HORIZONTAL FACE LENGTH (15 ft. max.)

Weep baffles are cut from (1) HCW6, halved, to provide (2)
2" x 3/8" x 1/2" weep baffles. See Fig. 17 below.

Due to the expansion characteristics of the aluminum face member
and also to maintain the 1/4" splice joint, 15 feet is the
recommended cut length for the face member.

1/2"

2"

HCW6

5/8"

3/4"

NOTE:

STEP 2)

{

[FIG. 17]

48" O.C.

2"

1/2"

[FIG. 16]

1/4"

D.L.O.

Splice ONLY at center lines of vertical mullions.

of 15’-0"). Allow 1/4" at splice joints for expansion.

Cut horizontal face member to span 3 lites (or a maximum

SECTION III G - FABRICATION

See Fig. 16 below.

STEP 1)

D.L.O.

2"

D.L.O.

2"

2"

Advertising