Fig. 19, Step 4), Chart b – EFCO 904 Series User Manual
Page 26
Advertising

Figure the splice joint location to fall at the center line of a
INTERMEDIATE HORIZONTAL
CUT LENGTH FOR FACE MEMBER = 3 Lites - Not to exceed 15’
CUT LENGTH FOR GLASS STOP = D.L.O. MINUS 1/32".
NEAT APPEARANCE
CLEAN EXCESS FOR A
FILL VOID WITH SILICONE
CENTER LINE OF VERTICAL MULLION
[FIG. 19]
EXPANSION JOINT
1/4"
vertical mullion, with respect to the 3 lite/15’ guideline.
SILICONE ONE END ONLY.
SET SPLICE PLATES IN
STEP 4)
903 - 3 1/4"
904 - 4"
& DEPTH
SYSTEM
901 - 4 1/2"
902 - 5 1/4"
INTERM. HORIZ.
EXTRUSION NOS.
9586/9566/9565
9564/9566/9565
[CHART B]
9469/9587/9565
8583/8584/8499
K-141
K-141
REQUIRED
SHEAR BLOCK
K-176
K-176
SECTION III G - FABRICATION
at BUTT GLAZE VERTICAL APPLICATIONS.
VERTICAL to VERTICAL - INTERIOR D.L.O.
DPS 7/2001