31
Check your wiring against the overview in Figure 45. Note that the TAP spade connector on the rectifier
board is not yet used, and there are five spade connectors on the power supply board (four hidden under the
large ribbon cable) that are not yet used. They will be filled with leads from the power transformer installed in
the following steps.
Figure 45. Overview of Power Supply Wiring Before Installing Power Transformer.
Temporarily remove the left side panel to provide room to install the power transformer. Remove the
screws shown in Figure 14 plus the screw in the 2D fastener at the top rear corner. Do not remove the two
screws holding the interlock switch (Figure 12). Unplug the interlock switch from the power supply board as
you remove the panel.