Startup Procedures - All Systems - Flushing the System

FLUSHING THE SYSTEM

18.

With the inlet side of the Bypass Valve still only PARTIALLY open and the tank still filling slowly - it is time to

manually backwash and flush the system.

CAUTION:

The outlet side of the Bypass Valve remains closed and in the bypass position until this flushing procedure has

been completed

19.

Manually start a backwash to flush the system.

Press and hold (5 seconds) the Extra Cycle Button until the Parameter Display flashes “BW” and the Data

Display reads “----”.

You will hear the valve engage and it will take about 1 minute (60 seconds) until the backwash “BW”

cycle is reached.

Once the backwash “BW” cycle begins the Parameter Display will stop flashing and reads “BW” and

the Data Display is counting down from 9:59 in 1 second increments. This backwash is a 10 minute cycle.

17.

While tank is slowly filling, Set the Time of Day by presssing either the Up or Down Button.

The Parameter Display will read “TD” for Time of Day and the Programming Icon will appear

Continue to press either Up or Down Button until the Data Display reads the current time of day.

If after 12:00 (noon) then the PM Indicator should be lit.

Once set, allow up to 10 seconds and the “TD” and will disappear.

What you will see on the display:

Current Time of Day, a PM Indicator (if applicable)

You will also see the Time of Day alternate (about every 10 seconds) to another number and than back to

the time of day - this is normal and tells the user the next time the system will backwash counting down

each day from 6 (factory pre-set) until backwash.

In Service Icon

The diagram to the right is an

illustration of the system valve

controls and all the displays

for your reference.

Please follow the directions

above to set the time of day.

Please follow the directions

below to manually advance

the system through each step

of the backwash and flushing

procedure.

SETTING THE TIME OF DAY WHILE THE TANK IS FILLING SLOWLY

Parameter

Display

Data

Display

PM

Indicator

In Service

Icon

Error

Information

Icon

Programming Icon

Extra Cycle

Button

Up

Button

Down

Button

Advertising