ISSPRO R8905 User Manual

Page 2

Advertising
background image

Form No. 420A (2/4/03 Rev. B) Page 2 of 2

(Optional)

MOUNTING HARDWARE

TOP VIEW

OF ENGINE

INSTALLATION DIAGRAM R8504 2 1/16" TACHOMETER

ISUZU DIESEL ENGINE

USING: R8905 SENSOR KIT

!! BEFORE GLUING MAGNETS !!

#20 AWG (or larger)

EXTENSION WIRES

(Not Furnished)

(length to suit).

MAGNET PAIR: R8911
MOUNT: Blue Side Out

MOUNTING
BRACKET

14mm BOLT

APPX. 1/4"

12mm BOLT

#10 HARDWARE
(Use Thread Sealer)

SENSOR

FRONT OF ENGINE

2. ROUGHEN PULLEY SURFACE WITH COARSE SANDPAPER.

SWITCHED +12 VDC.

RED WIRE: CONNECT TO IGNITION

WHITE WIRE TO SENSOR

3. CLEAN MAGNET & PULLEY SURFACES WITH ALCOHOL.

1. SCRAPE AWAY PAINT.

MOUNTING BRACKET

ISSPRO R8504 TACHOMETER

3 WIRE CABLE

OTHER WIRE TO GROUND

ONE WIRE TO DASH LIGHT CIRCUIT

SENSOR WIRES

BLUE SIDE

ENGINE PULLEY

STEP

BLACK WIRE TO SENSOR

AND TO GROUND.

MOUNTING BRACKET

Advertising