4

Find a location where transmission pressure can be measured, such as a test port on the transmission.
This may require adapter fittings to accommodate the ⅛” NPTF sensor threads (ISSPRO R78844,
R78877, and R78888 may be purchased separately).

Only use this sensor & gauge for applications that will not exceed 400 psi of pressure.

5

Install the new sensor. Pressure sensor threads are ⅛” NPTF.

Many Emission Control Devices are connected to temperature sensors or switches. Be careful not

to disable these when installing a sensor.

6

If leakage occurs at the sensor, tighten one-quarter turn at a time until leakage stops. If necessary,
thread sealant such as Teflon tape may be used.

When using a torque wrench, tighten approximately 20nm/15 lb-in. or slightly more, if leakage

occurs. Do not use the body of the sensor to tighten! Use only the hex and the correct wrench. Do
not over tighten!

7

Connect the pressure sensor to the pressure sensor harness by pressing the connector into the

slot.

Figure

3: Pressure sensor and harness.

8

Connect transmission pressure gauge to the ESP. (See ESP instructions for more details on how

to do this). Note: If drilling a mounting hole in a panel to mount this gauge, the hole size should be
2.040”.

9

Secure all wiring so that it does not interfere with moving parts or chafe on sharp edges. This may

be accomplished by routing the wiring within the factory wire harness sheath, using wire ties and
sheathing, and using appropriate grommets when passing through the firewall.