Just Better Deep Vacuum Pump Cartridge User Manual

Page 2

Advertising
background image

FIG. 4

FIG. 5

FIG. 6

FIG. 7

REMOVING OIL COVER

1. Using 3/16" Allen wrench remove

6 socket head cap screws from

oil cover. (FIG. 4)

REMOVING CARTRIDGE

1. Remove 4 cartridge screws (7/16"

or 3/8" wrench) (FIG. 5). Discard

old gasket seal and 2 O-rings

along with cartridge and bolts.

REPLACING SHAFT SEAL

AND O-RINGS

1. Insert screwdriver blade under

shaft seal and pry the seal from

the housing being careful not to

damage the walls or face of the

trap. (FIG. 6)

2. With clean rag remove all oil and

residue from inside hole and front

and back of trap.

3. Lay trap on flat surface with

handle toward you. Press new

shaft seal with flat side down into

opening by hand. To seat, tap

seal with 11/16" socket. Seal is

properly seated 1/8" down from

top edge (FIG. 7). Apply vaseline

or grease to inside edges of seal.

4. Insert intake and gas ballast

O-rings in trap (FIG. 8). Gasket

replaced after cartridge is

installed.

REPLACING

PUMP CARTRIDGE

Read section carefully before at-

tempting replacement.
1. Keep trap flat on bench. Remove

holding nuts from cartridge,

keeping all parts in alignment.

(Four nuts can be discarded.)
Cartridge is held with shaft down

and flutter valves facing intake fit-

ting. Center shaft with seal open-

ing. (FIG. 9) Align with threaded

holes and place in position. Hand

tighten four bolts. Cross tighten

with 7/16" wrench.

2. Check alignment by rotating shaft

with coupler. If shaft moves freely

continue assembly. If shaft binds,

loosen bolts and turn shaft until

shaft rotates freely. Retighten

bolts. Shaft should be concentric

with shaft hole when viewed from

backside. (FIG. 10)

3. Replace gasket (FIG. 8) and re-

install oil cover to trap. (FIG. 4)

4. Remove setscrews on coupler.

Coat setscrew threads with

thread sealant. Re-install cou-

pling to pump cartridge with set

screw facing flat side of shaft .

Tighten screw so coupler slides

on shaft but stops at bottom of

flat. Tighten until screw head is

flush with coupler. Coupler should

be approximately 1/8" off trap

surface. (FIG. 11)

FIG. 9

FIG. 10

FIG. 8

FIG. 11 (Coupler styles may vary from illustration.)

1/8"

Bottom

Of Flat

Bottom of Flat Correct Incorrect

OIL LEVEL

1

2

3

4

5

6

Cover

Seal

Intake

O-Ring

Gas Ballast

O-Ring

Do not disturb

hex setting

screws

1

2

4

3

Shaft Aligned

Correctly

Shaft Touching Edge

Of Trap Hole

Align

Gas Ballast

Holes

If new intake plate on

cartridge differs from the

old intake plate use the old

intake plate.

Intake

Valve

11/16"
socket

Advertising