Power Connections

Warning

Read the installation instructions before connecting the system to the power source. Statement 1004

Note

The installation must comply with all required electrical codes applicable at the installation site.

Connecting Routers to AC Power

If your router uses AC power, connect it to a 15 A, 120 VAC (10 A, 240 VAC) circuit with overcurrent protection.

Note

The input voltage tolerance limits for AC power are 85 and 264 VAC.

Warning

AC connected units must have a permanent ground connection in addition to the power cable ground wire.
NEBS-compliant grounding satisfies this requirement.
Statement 284

Warning

This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than:
15A, 120VAC (10A, 240VAC).
Statement 1005

Connecting the Router to DC Power

If your router has a DC-input power supply, follow the directions in this section for proper wiring.

Warning

This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than:
15A, 60VDC.
Statement 1005

Warning

Use copper conductors only. Statement 1025

DC Wiring Requirements

A Cisco router with a DC-input power supply requires copper wire for the power connections. Table 2 summarizes the wiring
requirements for Cisco 2600XM series and Cisco 2612 routers with a DC-input power supply.

Note

For installations compliant with the National Electric Code, AWG 14 (2.0 mm

2

) wire is required for DC input and

safety ground wire.

Table 2

DC Wiring Requirements for Cisco 2610, Cisco 2620, and Cisco 2650 Series Routers

DC Power Source

DC Input

DC Input Wire Size

1

1. See the note above this table for National Electric Code wire size requirements.

Safety Ground Wire Size Overcurrent Protection

Nominal 48 VDC

–48 to –60 VDC

2

, 4 A

2. The input voltage tolerance limits for nominal 48-V power supplies are 38 and 72 VDC.

AWG 18 (1.0 mm

2

)

AWG 14 (2.0 mm

2

)

15 A, maximum