JRexplus-DC User's Guide

7.8.1 Jumper

Settings

The jumper J5 can be used to set the backlight supply voltage to 5V or 12V.

1


The jumper J3 can be used to invert the backlight-on signal of the backlight inverter.

1

Pins

Backlight Voltage

1 - 2

5V

2 - 3

12V

Pins

Backlight-On

1 - 2

High

2 - 3

Low