PD15: CP3-SVE-M100DC
CPCI Power Supply
RID 24139 PD15, Rev.02
Operating Data
Overtemperature protection
Shutdown at +97°C to 103°C baseplate
temperature with about 10°C hysteresis and
auto recovery.
Signal DEG (Derate)
Open-collector output, low active
Signal FAL (False)
Open-collector output, low active
Input EN (enable)
Input INH (inhibit)
Power is ON only with EN low (TTL)
Power always OFF with INH low (TTL)
Status indications
LED’s for:
Power Good / Error
all output voltages activated = green
voltage out of tolerance, over heating or
other error = red
Input Power
Vin > 16.8V DC = green
Vin < 16.8V DC = red
Temperature range: operating
Temperature range: storage
-40°C..+70°C with free convection
+85°C for 10 minutes
-40°C..+100°C
Warning!
Adequate thermal cooling of the power supply must be ensured.
Therefore do not obstruct or hinder cooling air circulation or heat con-
duction within the power supply or surrounding equipment.
Failure to comply with this warning may result in damage to your
equipment.