Page 10

PD15: CP3-SVE-M100DC

CPCI Power Supply

RID 24139 PD15, Rev.02

Operating Data

Overtemperature protection

Shutdown at +97°C to 103°C baseplate
temperature with about 10°C hysteresis and
auto recovery.

Signal DEG (Derate)

Open-collector output, low active

Signal FAL (False)

Open-collector output, low active

Input EN (enable)

Input INH (inhibit)

Power is ON only with EN low (TTL)

Power always OFF with INH low (TTL)

Status indications

LED’s for:

Power Good / Error
all output voltages activated = green
voltage out of tolerance, over heating or
other error = red

Input Power
Vin > 16.8V DC = green
Vin < 16.8V DC = red

Temperature range: operating

Temperature range: storage

-40°C..+70°C with free convection
+85°C for 10 minutes
-40°C..+100°C

Warning!

Adequate thermal cooling of the power supply must be ensured.
Therefore do not obstruct or hinder cooling air circulation or heat con-
duction within the power supply or surrounding equipment.
Failure to comply with this warning may result in damage to your
equipment.