CPCI Power Supply

PD15: CP3-SVE-M100DC

RID 24139 PD15, Rev.02

2.3

Installation

Thanks to its plug-in compatibility this DIN M-type power supply unit allows for an easy instal-
lation, by which the power supply unit’s male DIN M24/8 power connector is inserted into the
backplane’s mating female connector without the need of any intermediate adaptation.

Warning!
To ensure a safe 5V operation of your equipment it is necessary that
on the backplane 5VL is connected to 5VF and 0VL to 0VF.
The maximum voltage compensation is +/- 0.15V per line.

Warning!
Handling of a hot power supply unit with bare hands can cause burns.
This power supply unit will get hot during operation. Under constant
maximum load the front panel temperature can be up to 15°C higher
than the ambient air temperature. In addition, the PSU heat sink and
metal housing may reach temperatures in excess of 85°C.
To replace a hot PSU, wear thermal protective gloves. Allow sufficient
cooling down of a hot PSU before further handling with bare hands.
Kontron will not accept liability for any injuries or damages, directly or
indirectly resulting from failure to comply with the above warning.

Note ...
If the main power input is switched off, the supply voltages will not go
to 0V instantly. It will take a couple of seconds until the capacitors are
discharged. If the voltage rises again before it has gone below a cer-
tain level, the circuits may enter a latch-up state where even a hard
RESET will not help any more. The system must be switched off for at
least 3 seconds before it may be switched on again. If problems still
occur, turn off the main power for 30 seconds before turning it on
again.